AT89C51 MICROCONTROLLER NOTES


AT89C51 MICROCONTROLLER

 FEATURES
 80C51 based architecture
Ø       4-Kbytes of on-chip Reprogrammable Flash Memory
Ø       128 x 8 RAM
Ø       Two 16-bit Timer/Counters
Ø       Full duplex serial channel
Ø       Boolean processor
Ø       Four 8-bit I/O ports, 32 I/O lines
Ø       Memory addressing capability
        64K ROM and 64K RAM
Ø       Power save modes:
        Idle and power-down
Ø       Six interrupt sources
Ø       Most instructions execute in 0.3 us
Ø       CMOS and TTL compatible
Ø       Maximum speed: 40 MHz @ Vcc = 5V
Ø       Industrial temperature available
Ø       Packages available:
           – 40-pin DIP
           – 44-pin PLCC
           – 44-pin PQFP









GENERAL DESCRIPTION:

  THE MICROCONTROLLER:
            A microcontroller is a general purpose device, but that is meant to read data, perform limited calculations on that data and control its environment based on those calculations. The prime use of a microcontroller is to control the operation of a machine using a fixed program that is stored in ROM and that does not change over the lifetime of the system.
            The microcontroller design uses a much more limited set of single and double byte instructions that are used to move data and code from internal memory to the ALU. The microcontroller is concerned with getting data from and to its own pins; the architecture and instruction set are optimized to handle data in bit and byte size.
            The AT89C51 is a low-power, high-performance CMOS 8-bit microcontroller with 4k bytes of Flash Programmable and erasable read only memory (EROM). The device is manufactured using Atmel’s high-density nonvolatile memory technology and is functionally compatible with the industry-standard 80C51 microcontroller instruction set and pin out. By combining versatile 8-bit CPU with Flash on a monolithic chip, the Atmel’s AT89c51 is a powerful microcomputer, which provides a high flexible and cost- effective solution to many embedded control applications. 


      












Pin configuration of AT89c51 Microcontroller










 AT89C51 Block Diagram






 PIN DESCRIPTION:

VCC
     Supply voltage
GND
   Ground

Port 0
Port 0 is an 8-bit open drain bi-directional I/O port. As an output port, each pin can sink eight TTL inputs. When 1s are written to port 0 pins, the pins can be used as high impedance inputs.
            Port 0 can also be configured to be the multiplexed low order address/data bus during access to external program and data memory. In this mode, P 0 has internal pull-ups. Port 0 also receives the code bytes during Flash programming and outputs the code bytes during program verification. External pull-ups are required during program verification.

Port 1
            Port 1 is an 8-bit bi-directional I/O port with internal pull-ups. The port 1output buffers can sink/source four TTL inputs. When 1s are written to port 1 pins, they are pulled high by the internal pull-ups can be used as inputs. As inputs, Port 1 pins that are externally being pulled low will source current (1) because of the internal pull-ups.

Port 2
            Port 2 is an 8-bit bi-directional I/O port with internal pull-ups. The port 2 output buffers can sink/source four TTL inputs. When 1s are written to port 2 pins, they are pulled high  by the internal pull-ups can be used as inputs. As inputs, Port 2 pins that are externally being pulled low will source current because of the internal pull-ups.

            Port 2 emits the high-order address byte during fetches from external program memory and during access to DPTR. In this application Port 2 uses strong internal pull-ups when emitting 1s. During accesses to external data memory that use 8-bit data address (MOVX@R1), Port 2 emits the contents of the P2 Special Function Register. Port 2 also receives the high-order address bits and some control signals during Flash programming and verification.

Port 3
            Port 3 is an 8-bit bi-directional I/O port with internal pull-ups. The port 3 output buffers can sink/source four TTL inputs. When 1s are written to port 3 pins, they are pulled high by the internal pull-ups can be used as inputs. As inputs, Port 3 pins that are externally being pulled low will source current because of the internal pull-ups.

Port 3 also receives some control signals for Flash Programming and verification.

 Port pin
    Alternate Functions
P3.0
RXD(serial input port)
P3.1
TXD(serial input port)

P3.2
INT0(external interrupt 0)
P3.3
INT1(external interrupt 1)
P3.4
T0(timer 0 external input)
P3.5
T1(timer 1 external input)
P3.6
WR(external data memory write strobe)
P3.7
RD(external data memory read strobe)

RST
Rest input A on this pin for two machine cycles while the oscillator is running resets the device.




ALE/PROG:
            Address Latch Enable is an output pulse for latching the low byte of the address during access to external memory. This pin is also the program pulse input (PROG) during Flash programming.

            In normal operation ALE is emitted at a constant rate of 1/16 the oscillator frequency and may be used for external timing or clocking purpose. Note, however, that one ALE pulse is skipped during each access to external Data memory.
_____
PSEN
            Program Store Enable is the read strobe to external program memory when the AT89c51 is executing code from external program memory PSEN is activated twice each machine cycle, except that two PSEN activations are skipped during each access to external data memory.
__
EA /VPP
            External Access Enable (EA) must be strapped to GND in order to enable the device to fetch code from external program memory locations starting at 0000h up to FFFFH. Note, however, that if lock bit 1 is programmed EA will be internally latched on reset. EA should be strapped to Vcc for internal program executions. This pin also receives the 12-volt programming enable voltage (Vpp) during Flash programming when 12-volt programming is selected.

XTAL1

Input to the inverting oscillator amplifier and input to the internal clock operating circuit.

XTAL 2

 Output from the inverting oscillator amplifier.


 OPERATING DESCRIPTION

The detail description of the AT89C51 included in this description is:

• Memory Map and Registers

• Timer/Counters

• Interrupt System

 MEMORY MAP AND REGISTERS

Memory
            The AT89C51 has separate address spaces for program and data memory. The program and data memory can be up to 64K bytes long. The lower 4K program memory can reside on-chip. The AT89C51 has 128 bytes of on-chip RAM.

            The lower 128 bytes can be accessed either by direct addressing or by indirect addressing. The lower 128 bytes of RAM can be divided into 3 segments as listed below

1. Register Banks 0-3: locations 00H through 1FH (32 bytes). The device after reset defaults to register bank 0. To use the other register banks, the user must select them in software. Each register bank contains eight 1-byte registers R0-R7. Reset initializes the stack point to location 07H, and is incremented once to start from 08H, which is the first register of the second register bank.

2. Bit Addressable Area: 16 bytes have been assigned for this segment 20H-2FH. Each one of the 128 bits of this segment can be directly addressed (0-7FH). Each of the 16 bytes in this segment can also be addressed as a byte.

3. Scratch Pad Area: 30H-7FH are available to the user as data RAM. However, if the data pointer has been initialized to this area, enough bytes should be left aside to prevent SP data destruction.


SPECIAL FUNCTION REGISTERS
            The Special Function Registers (SFR's) are located in upper 128 Bytes direct addressing area. The SFR Memory Map in shows that.
            Not all of the addresses are occupied. Unoccupied addresses are not implemented on the chip. Read accesses to these addresses in general return random data, and write accesses have no effect. User software should not write 1s to these unimplemented locations, since they may be used in future microcontrollers to invoke new features. In that case, the reset or inactive values of the new bits will always be 0, and their active values will be 1.
The functions of the SFR’s are outlined in the following sections.


Accumulator (ACC)
ACC is the Accumulator register. The mnemonics for Accumulator-specific instructions, however, refer to the Accumulator simply as A.
B Register (B)
The B register is used during multiply and divide operations. For other instructions it can be treated as another scratch pad register.
Program Status Word (PSW)
The PSW register contains program status information.
Stack Pointer (SP)

The Stack Pointer Register is eight bits wide. It is incremented before data is stored during PUSH and CALL executions. While the stack may reside anywhere in on chip RAM, the Stack Pointer is initialized to 07H after a reset. This causes the stack to begin at location 08H.
Data Pointer (DPTR)
The Data Pointer consists of a high byte (DPH) and a low byte (DPL). Its function is to hold a 16-bit address. It may be manipulated as a 16-bit register or as two independent 8-bit registers.
Serial Data Buffer (SBUF)
The Serial Data Buffer is actually two separate registers, a transmit buffer and a receive buffer register. When data is moved to SBUF, it goes to the transmit buffer, where it is held for serial transmission. (Moving a byte to SBUF initiates the transmission.) When data is moved from SBUF, it comes from the receive buffer.
Timer Registers
Register pairs (TH0, TL0) and (TH1, TL1) are the 16-bit Counter registers for Timer/Counters 0 and 1, respectively.
Control Registers
Special Function Registers IP, IE, TMOD, TCON, SCON, and PCON contain control and status bits for the interrupt system, the Timer/Counters, and the serial port.




 TIMER/COUNTERS

            The IS89C51 has two 16-bit Timer/Counter registers: Timer 0 and Timer 1. All two can be configured to operate either as Timers or event counters. As a Timer, the register is incremented every machine cycle. Thus, the register counts machine cycles. Since a machine cycle consists of 12 oscillator periods, the count rate is 1/12 of the oscillator frequency.
            As a Counter, the register is incremented in response to a 1-to-0 transition at its corresponding external input pin, T0 and T1. The external input is sampled during S5P2 of every machine cycle. When the samples show a high in one cycle and a low in the next
cycle, the count is incremented. The new count value appears in the register during S3P1 of the cycle following the one in which the transition was detected. Since two machine cycles (24 oscillator periods) are required to recognize a 1-to-0 transition, the maximum count rate is 1/24 of the oscillator frequency. There are no restrictions on the duty cycle of the external input signal, but it should be held for at least one full machine cycle to ensure that a given level is sampled at least once before it changes.

In addition to the Timer or Counter functions, Timer 0 and Timer 1 have four operating modes: 13-bit timer, 16-bit timer, 8-bit auto-reload, split timer.

TIMERS:








SFR’S USED IN TIMERS
The special function registers used in timers are,

  • TMOD Register
       
  • TCON  Register

  • Timer(T0) & timer(T1) Registers

(i) TMOD Register:

TMOD is dedicated solely to the two timers (T0 & T1).

  • The timer mode SFR is used to configure the mode of operation of each of the two timers. Using this SFR your program may configure each timer to be a 16-bit timer, or 13 bit timer, 8-bit auto reload timer, or two separate timers. Additionally you may configure the timers to only count when an external pin is activated or to count “events” that are indicated on an external pin.
  • It can consider as two duplicate 4-bit registers, each of which controls the action of one of the timers.

(ii) TCON Register:

·        The timer control SFR is used to configure and modify the way in which the 8051’s two timers operate. This SFR controls whether each of the two timers is running or stopped and contains a flag to indicate that each timer has overflowed. Additionally, some non-timer related bits are located in TCON SFR.
·        These bits are used to configure the way in which the external interrupt flags are activated, which are set when an external interrupt occurs.
           


(iii) TIMER 0 (T0):

  • TO (Timer 0 low/high, address 8A/8C h)
These two SFR’s taken together represent timer 0. Their exact behavior depends on how the timer is configured in the TMOD SFR; however, these timers always count up. What is configurable is how and when they increment in value.



(iv) TIMER 1 (T1):

  • T1 (Timer 1 Low/High, address 8B/ 8D h)
These two SFR’s, taken together, represent timer 1. Their exact behavior depends on how the timer is configured in the TMOD SFR; however, these timers always count up. What is Configurable is how and when they increment in value.


The Timer or Counter function is selected by control bits C/T in the Special Function Register TMOD. These two Timer/Counters have four operating modes, which are selected by bit pairs (M1, M0) in TMOD. Modes 0, 1, and 2 are the same for both Timer/Counters, but Mode 3 is different.

The four modes are described in the following sections.


Mode 0:
            Both Timers in Mode 0 are 8-bit Counters with a divide-by-32 pre scalar. Figure 8 shows the Mode 0 operation as it applies to Timer 1. In this mode, the Timer register is configured as a 13-bit register. As the count rolls over from all 1s to all 0s, it sets the Timer interrupt flag TF1. The counted input is enabled to the Timer when TR1 = 1 and either GATE = 0 or INT1 = 1. Setting GATE = 1 allows the Timer to be controlled by external input INT1, to facilitate pulse width measurements. TR1 is a control bit in the Special Function Register TCON. Gate is in TMOD.
           
            The 13-bit register consists of all eight bits of TH1 and the lower five bits of TL1. The upper three bits of TL1 are indeterminate and should be ignored. Setting the run flag (TR1) does not clear the registers.

            Mode 0 operation is the same for Timer 0 as for Timer 1, except that TR0, TF0 and INT0 replace the corresponding Timer 1 signals. There are two different GATE bits, one for Timer 1 (TMOD.7) and one for Timer 0 (TMOD.3).


Mode 1
            Mode 1 is the same as Mode 0, except that the Timer register is run with all 16 bits. The clock is applied to the combined high and low timer registers (TL1/TH1). As clock pulses are received, the timer counts up: 0000H, 0001H, 0002H, etc. An overflow occurs on the FFFFH-to-0000H overflow flag. The timer continues to count. The overflow flag is the TF1 bit in TCON that is read or written by software

Mode 2
            Mode 2 configures the Timer register as an 8-bit Counter (TL1) with automatic reload, as shown in Figure 10. Overflow from TL1 not only sets TF1, but also reloads TL1 with the contents of TH1, which is preset by software. The reload leaves the TH1 unchanged. Mode 2 operation is the same for Timer/Counter 0.

Mode 3
            Timer 1 in Mode 3 simply holds its count. The effect is the same as setting TR1 = 0. Timer 0 in Mode 3 establishes TL0and TH0 as two separate counters. The logic for Mode 3 on Timer 0 is shown in Figure 11. TL0 uses the Timer 0 control bits: C/T, GATE, TR0, INT0, and TF0. TH0 is locked into a timer function (counting machine cycles) and over the use of TR1 and TF1 from Timer 1. Thus, TH0 now controls the Timer 1 interrupt.
            Mode 3 is for applications requiring an extra 8-bit timer or counter. With Timer 0 in Mode 3, the AT89C51 can appear to have three Timer/Counters. When Timer 0 is in Mode 3, Timer 1 can be turned on and off by switching it out of and into its own Mode 3. In this case, Timer 1 can still be used by the serial port as a baud rate generator or in any application not requiring an interrupt.

INTERRUPT SYSTEM
            An interrupt is an external or internal event that suspends the operation of micro controller to inform it that a device needs its service. In interrupt method, whenever any device needs its service, the device notifies the micro controller by sending it an interrupt signal. Upon receiving an interrupt signal, the micro controller interrupts whatever it is doing and serves the device. The program associated with interrupt is called as interrupt service subroutine (ISR).Main advantage with interrupts is that the micro controller can serve many devices.   

Baud Rate
            The baud rate in Mode 0 is fixed as shown in the following equation. Mode 0 Baud Rate = Oscillator Frequency /12 the baud rate in Mode 2 depends on the value of the SMOD bit in Special Function Register PCON. If SMOD = 0 the baud rate is 1/64 of the oscillator frequency. If SMOD = 1, the baud rate is 1/32 of the oscillator frequency.
Mode 2 Baud Rate = 2SMODx (Oscillator Frequency)/64.
In the IS89C51, the Timer 1 overflow rate determines the baud rates in Modes 1 and 3.


NUMBER OF INTERRUPTS IN 89C51:
            There are basically five interrupts available to the user. Reset is also considered as an interrupt. There are two interrupts for timer, two interrupts for external hardware interrupt and one interrupt for serial communication.
                         Memory location                          Interrupt name
                            0000H                                          Reset
                            0003H                                          External interrupt 0
                            000BH                                         Timer interrupt 0
                            0013H                                          External interrupt 1
                            001BH                                         Timer interrupt 1
                            0023H                                          Serial COM interrupt

            Lower the vector, higher the priority. The External Interrupts INT0 and INT1 can each be either level-activated or transition-activated, depending on bits IT0 and IT1 in Register TCON. The flags that actually generate these interrupts are the IE0 and IE1 bits in TCON. When the service routine is vectored, hardware clears the flag that generated an external interrupt only if the interrupt was transition-activated. If the interrupt was level-activated, then the external requesting source (rather than the on-chip hardware) controls the request flag.
            The Timer 0 and Timer 1 Interrupts are generated by TF0and TF1, which are set by a rollover in their respective Timer/Counter registers (except for Timer 0 in Mode 3).When a timer interrupt is generated, the on-chip hardware clears the flag that is generated.
            The Serial Port Interrupt is generated by the logical OR of RI and TI. The service routine normally must determine whether RI or TI generated the interrupt, and the bit must be cleared in software.
            All of the bits that generate interrupts can be set or cleared by software, with the same result as though they had been set or cleared by hardware. That is, interrupts can be generated and pending interrupts can be canceled in software.

            Each of these interrupt sources can be individually enabled or disabled by setting or clearing a bit in Special Function Register IE (interrupt enable) at address 0A8H. There is a global enable/disable bit that is cleared to disable all interrupts or to set the interrupts.

IE (Interrupt enable register):
 Steps in enabling an interrupt:

            Bit D7 of the IE register must be set to high to allow the rest of register to take effect. If EA=1, interrupts are enabled and will be responded to if their corresponding bits in IE are high. If EA=0, no interrupt will be responded to even if the associated bit in the IE register is high.

Description of each bit in IE register:

            D7 bit: Disables all interrupts. If EA =0, no interrupt is acknowledged, if EA=1 each interrupt source is individually enabled or disabled by setting or clearing its enable bit.

D6 bit: Reserved.
D5 bit: Enables or disables timer 2 over flow interrupt (in 8052).
D4 bit: Enables or disables serial port interrupt.
D3 bit: Enables or disables timer 1 over flow interrupt.
D2 bit: Enables or disables external interrupt 1.
D1 bit: Enables or disables timer 0 over flow interrupt.
D0 bit: Enables or disables external interrupt 0.





Interrupt priority in 89C51:
            There is one more SRF to assign priority to the interrupts which is named as interrupt priority (IP). User has given the provision to assign priority to one interrupt.  Writing one to that particular bit in the IP register fulfils the task of assigning the priority.

 Description of each bit in IP register:

D7 bit: Reserved.
 D6 bit: Reserved.
D5 bit: Timer 2 interrupt priority bit (in 8052).
D4 bit: Serial port interrupt priority bit.
D3 bit: Timer 1 interrupt priority bit.
D2 bit: External interrupt 1 priority bit.
D1 bit: Timer 0 interrupt priority bit.
D0 bit: External interrupt 0 priority bit.