Terminology
Zone – refers to an alarm control panel’s input from a protective
circuit which divides the alarm system into separate independent areas
of protection based on function which may include medical, fire,
intrusion, or critical condition monitoring
Burglar Alarm - one way of preventing break-in’s into one’s property,
not only to protect the possessions but the occupants as well; can
prevent the havoc and disruption caused by theft and break-in’BC547 –
NPN small signal transistors designed for general purpose switching and
amplification due to its low voltage, low current and three different
gain selections CMOS 4011 – a quad 2-input NAND gate integrated circuit,
generally characterized by small fluctuation in voltage supply, very
high impedance, outputs that can sink and source, one output can drive
up to 50 inputs, high speed gate propagation time, high frequency, and
low power consumption
The zone designed in this circuit contains automatic entry and exit intervals with a
bell having its cut off timer. It can also be applicable to other
normally open and normally closed switches that contains input devices
such as magnetic reed contacts, pressure mats, foil tapes, inertia
sensors and passive infrared detectors. The buzzer will sound if the
alarm is switched on wherein the loop is in open stage. On theother
hand, as the switch turns off, the loop becomes a closed circuit again.
The alarm will operate with any type of two-way switch.
The
circuit is being powered by a 12 V supply, which is enough for as long
as the buzzer, siren, and relay will match the supply input. The
basicoperation of the alarm occurs with the
interruption of electric current to a relay cause by deenergizing of
the relay and making the relay contacts to operate the alarm indicator.
The circuit is applicable to a single zone which can consist of a single
point of contact. To start the circuit to function, the switch S1
should be set accordingly, but before doing this, all the LED should be
properly lighting. Once the switch has been set, there will be an
allotted thirty seconds to leave the premises which will trigger the
buzzer to sound. It will only stop sounding when the door has been
closed. In doing this procedure, it will ensure that the entry and exit
operation has been restored effectively. Upon re-entering the premises,
there will be 30 seconds time allotment to turn OFF the switch SW1.
Failing to do this will trigger and energize the relay and eventually
sound the siren. This can be deactivated at any time by turning OFF SW1.
The alarm will reset, the relay will de-energize, and the siren will be
cut-off once the loop has been restored after 15 minutes.
The delay timers in the circuit depend largely on the values and
characteristics of the components used in the circuit, due to the
manufacturing tolerances. The entry, exit and bell cut-off timer can be
modified by altering the values of resistors R9, R6 and R3 depending on
the prerequisite. By decreasing the values, the timer will also
decrease; same thing with increasing the values will increase the timing.
Application:
A
burglar alarm system helps detect unauthorized entry onto a company’s
premises. The system sends a signal to a central monitoring center when
activated. The monitoring centers provide 24/7 service and will alert
the local police to dispatch authorities to the scene. It is a proven
fact that the risk of burglary is significantly reduced after a burglar
alarm is installed.